Abstract
The temperature field of artificial freezing curtain is a transient temperature field changing with time. In order to ensure the safety of the project, improve the timeliness and accuracy of temperature measurement, and ensure the safety strength and effective water sealing of the curtain, it is necessary to implement the information temperature monitoring control for the freezing process. According to the application environment of the freezing monitoring for the long distance and multi measuring points in the construction of the coal mine over a kilometre, a monitoring system of the frozen deep wells which is developed by the 1-wire bus technology is proposed. By using high-performance single chip microcomputer, designing pull-up and level detection driving circuit, matching cable characteristic impedance and distributing digital temperature measurement cable, the 1-wire bus network monitoring points can reach 55 and the transmission distance is over 1000 m, which meets the current monitoring requirements of frozen deep wells.
Similar content being viewed by others
Data availability
The data used to support the findings of this study are included within the article.
References
Xiaomin Z, Mengshu W, Longguang T, Songshan Y (2003) Model test and prototype observation on artificial ground freezing and tunneling of Beijing subway. Chin J Geotech Eng 25:676–679. https://doi.org/10.3321/j.issn:1000-4548.2003.06.006
Li Z, Chen J, Sugimoto M, Ge H (2019) Numerical simulation model of artificial ground freezing for tunneling under seepage flow conditions. Tunn Undergr Sp Technol 92:103035. https://doi.org/10.1016/j.tust.2019.103035
Chang DK, Lacy HS (2008) Artificial ground freezing in geotechnical engineering. In: International conference on case histories in geotechnical engineering, pp 1–11
Ito Y, Yoshida S (2016) Transition of ground improvement technologies in Japan V: artificial ground freezing method and its application. J Soc Mater Sci Jpn 65:883–889. https://doi.org/10.2472/jsms.65.883
Zhou XM, Zhang XZ (2003) Research on the thickness estimation of freezing wall according to temperature measurement along freeze tube. J China Coal Soc 28:162. https://doi.org/10.3321/j.issn:0253-9993.2003.02.012
Yansen W, Jiahui H, Weihao Y et al (2006) Temperature measurement of outer shaft wall during freezing sinking in deep alluvium. J China Univ Min Technol 35:468–472. https://doi.org/10.3321/j.issn:1000-1964.2006.04.009
Yan Q, Wu W, Zhang C et al (2019) Monitoring and evaluation of artificial ground freezing in metro tunnel construction—a case study. KSCE J Civ Eng 23:2359–2370. https://doi.org/10.1007/s12205-019-1478-z
Xuan W, Lai A (2017) Design of temperature monitoring system based on micro-controller. In: Proceedings of the 2017 5th international conference on machinery, materials and computing technology (ICMMCT 2017). Atlantis Press, pp 418–421
Nor Asiah Binti Ahmad sukori (2010) Development of wireless type K thermocouple temperature
Jingzhuo W, Chenglong G (2007) Research on 1-wire bus temperature monitoring system. In: 2007 8th international conference on electronic measurement and instruments, pp 3–726
Zhang Q (2010) Design of digital thermometer based on AT89C52 single chip microcontroller. In: Proceedings of the international conference on electrical control engineering ICECE 2010, pp 725–727. https://doi.org/10.1109/iCECE.2010.185
Xiangdong H, Ruifeng L (2007) Temperature Monitoring System for Freezing Method Based on “1-wire Bus”. Chin J Undergr Sp Eng 3:937–940. https://doi.org/10.3969/j.issn.1673-0836.2007.05.031
Zhang C, Feng X, Li L (2010) The key technologies of a distributed temperature monitoring system based on 1-wire bus. In: Proceedings of the world congress on intelligent control and automation (WCICA). IEEE, pp 7041–7045
Hongmei X, Shaorui J, Li Y (2007) Development of intelligent monitoring and control system of temperature measurement based on 1-wire bus. Ind Mine Autom. https://doi.org/10.3969/j.issn.1671-251X.2007.02.033
Yanzhong Z, Yuming Z (2011) Research and development of one line bus monitoring and measuring system for deep mine shaft ground freezing. Coal Sci Technol 39:104–107
Yuming Z, Changzhong L (2009) Research of distributed optical fiber temperature measurement system in freezing monitoring. Ind Mine Autom 35:55–58
Panteleev I, Kostina A, Zhelnin M et al (2017) Intellectual monitoring of artificial ground freezing in the fluid-saturated rock mass. Proc Struct Integr 5:492–499. https://doi.org/10.1016/j.prostr.2017.07.149
Wei Z, Bin S, Wenbin S et al (2007) Monitoring and application of distributed optical fiber sensors in transient temperature field of frozen soil. Chin J Geotech Eng 29:723–728. https://doi.org/10.3321/j.issn:1000-4548.2007.05.015
Zhu J, Wang J, Liu D (2011) Design of a wireless sensor network node based on nRF2401. In: 2011 IEEE international conference on computer science and automation engineering, pp 203–206
Tracey PM (1991) Intrinsic fiber-optic sensors. Trans Ind Appl 27:96–98
Guan L, Yongtao L, Xiangli B, Jie M (2015) Application of ZigBee and single bus in freezing shaft wall wireless temperature measurement system. Saf Coal Mines 46:116–118. https://doi.org/10.13347/j.cnki.mkaq.2015.03.035
Downs R (1998) Using 1-Wire I/O for distributed system monitoring. In: Wescon/98. conference proceedings (Cat. No.98CH36265), pp 161–168
Vavrla T, Koziorek J (2012) Temperature measurement in boreholes by programmable logic controller B&R and temperature sensors 1-wire. IFAC Proc 11:382–387. https://doi.org/10.3182/20120523-3-cz-3015.00073
Pimentel E, Papakonstantinou S, Anagnostou G (2012) Numerical interpretation of temperature distributions from three ground freezing applications in urban tunnelling. Tunn Undergr Sp Technol 28:57–69. https://doi.org/10.1016/j.tust.2011.09.005
Yenan W, Jianghua C (2015) Research on the stability of remote temperature information transmission. Process Autom Instrum 88–89: 93. https://doi.org/10.16086/j.cnki.issn1000-0380.201507023
Shaowei S, Yibao D, Gaoqin Z (2006) Research on temperature measuring network based on DS18B20. Process Autom Instrum 27:42–45. https://doi.org/10.3969/j.issn.1000-0380.2006.10.014
Ni S, Su J, Nie L, Qu S (2012) Design of multi-point wireless temperature measuring system. In: Proceedings of 2012 international conference on modelling, identification and control, ICMIC 2012, pp 422–425
Cheng-Ying Y, Yong C (2019) Research on multi-master communication system based on RS485 Bus. In: Journal of physics: conference series
Wang S, Zhao H, Zhu J (2016) Control and communication of a multi-motor system based on LAN. In: ICIIBMS 2015---international conference on intelligent informatics and biomedical sciences, pp 427–430
Dudak J, Tanuska P, Gaspar G, Fabo P (2018) ARM-based universal 1-wire module solution. J Sens https://doi.org/10.1155/2018/5268247
Acknowledgements
This work is supported by the National Key R&D Program of China during the 13th Five-year Plan Period (Grant No. 2016YFC0600803), the National Natural Science Foundation of China (Grant No. 5167082378) and Fundamental Research Funds for the Central Universities (Grant No. FRF-BD-18-007A).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflicts of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Wu, T., Zhou, X., He, X. et al. Design of distributed temperature-measuring system based on 1-wire bus for ultra-kilometre frozen deep well. Evol. Intel. 15, 2505–2514 (2022). https://doi.org/10.1007/s12065-020-00557-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12065-020-00557-8