1 January 2005 Second-harmonic magnetoresistive imaging to authenticate and recover data from magnetic storage media
David P. Pappas, A. V. Nazarov, D. Stevenson, Stephen D. Voran, Michael E. Read, E. M. Gormley, Jim Cash, Ken Marr, James J. Ryan
Author Affiliations +
Abstract
A scanning magnetoresistive (MR) microscope is developed for high-resolution imaging of magnetic tapes and digital media. Second-harmonic detection is used to remove thermal anomalies. We are able to image sufficient lengths of tape for authentication purposes and for data recovery from damaged samples. The second-harmonic technique provides high-contrast magnetic images of the magnetic storage media using high-resolution MR sensors from commercial hard disk drives. These images can be directly converted into the originally recorded analog audio waveforms or digital data.
©(2005) Society of Photo-Optical Instrumentation Engineers (SPIE)
David P. Pappas, A. V. Nazarov, D. Stevenson, Stephen D. Voran, Michael E. Read, E. M. Gormley, Jim Cash, Ken Marr, and James J. Ryan "Second-harmonic magnetoresistive imaging to authenticate and recover data from magnetic storage media," Journal of Electronic Imaging 14(1), 013015 (1 January 2005). https://doi.org/10.1117/1.1866150
Published: 1 January 2005
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetism

Sensors

Head

Signal to noise ratio

Analog electronics

Magnetic sensors

Magnetic resonance imaging

RELATED CONTENT

MEG beamforming: magnetic source imaging
Proceedings of SPIE (March 13 2009)
Channel modeling for hybrid magneto-optical recording
Proceedings of SPIE (September 18 2000)
Read heads for magnetic tapes
Proceedings of SPIE (January 15 1996)