Paper
8 March 2019 Endoscopic guidance system for stimulation of the laryngeal adductor reflex by droplet impact
Jacob Friedemann Fast, Adrian Karl Rüppel, Caroline Bärhold, Michael Jungheim, Tobias Ortmaier, Martin Ptok, Lüder Alexander Kahrs
Author Affiliations +
Abstract
Pathologies of protective laryngeal reflexes such as the laryngeal adductor reflex (LAR) can increase the risk of aspiration pneumonia, a potentially life-threatening inflammation of the lungs caused by the intrusion of foreign particles into the lower airways. To estimate this risk, a standardized and non-invasive LAR screening method is highly desirable. In previous work, a commercially available high-speed laryngoscope has been equipped with a pressurized fluid system to shoot droplets onto the laryngeal structures for LAR stimulation and subsequent reflex latency evaluation. This Micro-droplet Impulse Testing of the LAR (MIT-LAR) lacks droplet impact site prediction for an unbiased and stimulation site-dependent reflex latency assessment. In this work, a two- phase algorithm leveraging stereoscopic image data for droplet impact site prediction and visualization of this prediction in the laryngoscopic image is proposed. A high-speed stereolaryngoscope requiring only a single camera was designed from scratch by combining two rod lens optics in one common shaft. This setup was used for stereoscopic high-speed image data acquisition of droplets shot at different muzzle energies and endoscope roll angles. Surface reconstruction of the target region is performed using a phantom of the human larynx. The point of intersection between the reconstructed surface and the droplet trajectory approximation recorded previously at known droplet formation parameters is calculated. The proposed approach allows stimulation site prediction for an enhanced MIT-LAR procedure. Quantitative evaluation of impact site prediction accuracy for different droplet muzzle energies and nozzle inclinations yields an average prediction error of 2.9 mm (n = 20).
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jacob Friedemann Fast, Adrian Karl Rüppel, Caroline Bärhold, Michael Jungheim, Tobias Ortmaier, Martin Ptok, and Lüder Alexander Kahrs "Endoscopic guidance system for stimulation of the laryngeal adductor reflex by droplet impact", Proc. SPIE 10951, Medical Imaging 2019: Image-Guided Procedures, Robotic Interventions, and Modeling, 109510M (8 March 2019); https://doi.org/10.1117/12.2512852
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Endoscopes

Endoscopy

Visualization

Image visualization

Imaging systems

Algorithm development

High speed cameras

RELATED CONTENT


Back to Top