skip to main content
article

Veiling glare in high dynamic range imaging

Published:29 July 2007Publication History
Skip Abstract Section

Abstract

The ability of a camera to record a high dynamic range image, whether by taking one snapshot or a sequence, is limited by the presence of veiling glare - the tendency of bright objects in the scene to reduce the contrast everywhere within the field of view. Veiling glare is a global illumination effect that arises from multiple scattering of light inside the camera's body and lens optics. By measuring separately the direct and indirect components of the intra-camera light transport, one can increase the maximum dynamic range a particular camera is capable of recording. In this paper, we quantify the presence of veiling glare and related optical artifacts for several types of digital cameras, and we describe two methods for removing them: deconvolution by a measured glare spread function, and a novel direct-indirect separation of the lens transport using a structured occlusion mask. In the second method, we selectively block the light that contributes to veiling glare, thereby attaining significantly higher signal-to-noise ratios than with deconvolution. Finally, we demonstrate our separation method for several combinations of cameras and realistic scenes.

Skip Supplemental Material Section

Supplemental Material

pps037.mp4

mp4

44.7 MB

References

  1. Boynton, P. A., and Kelley, E. F. 2003. Liquid-filled camera for the measurement of high-contrast images. SPIE, D. G. Hopper, Ed., vol. 5080, 370--378.Google ScholarGoogle Scholar
  2. Debevec, P. E., and Malik, J. 1997. Recovering high dynamic range radiance maps from photographs. In Proceedings of ACM SIGGRAPH 1997, ACM Press/Addison-Wesley Publishing Co., New York, NY, USA, 369--378. Google ScholarGoogle ScholarDigital LibraryDigital Library
  3. Fattal, R., Lischinski, D., and Werman, M. 2002. Gradient domain high dynamic range compression. In ACM Transactions on Graphics, ACM Press, New York, NY, USA, 249--256. Google ScholarGoogle ScholarDigital LibraryDigital Library
  4. Faulkner, K., Kotre, C., and Louka, M. 1989. Veiling glare deconvolution of images produced by x-ray imageintensifiers. In Proceedings of the Third International Conference on Image Processing and its Applications, 669--673.Google ScholarGoogle Scholar
  5. Garg, G., Talvala, E.-V., Levoy, M., and Lensch, H. P. A. 2006. Symmetric photography: Exploiting data-sparseness in reflectance fields. In Proceedings of the Eurographics Symposium on Rendering, 251. Google ScholarGoogle ScholarCross RefCross Ref
  6. International Organization For Standardization. 1994. ISO 9358:1994: Optics and optical instruments - Veiling glare of image forming systems - Definitions and methods of measurement. International Organization for Standardization, Geneva, Switzerland.Google ScholarGoogle Scholar
  7. Kuwabara, G. 1953. On the flare of lenses. Journal of the Optical Society of America 43, 1, 53.Google ScholarGoogle ScholarCross RefCross Ref
  8. Mann, S., and Picard, R. W. 1995. Being 'undigital' with digital cameras: Extending dynamic range by combining differently exposed pictures. In IS&T 46th annual conference, 422--428.Google ScholarGoogle Scholar
  9. Matsuda, S., and Nitoh, T. 1972. Flare as applied to photographic lenses. Applied Optics 11, 8, 1850.Google ScholarGoogle ScholarCross RefCross Ref
  10. McCann, J. J., and Rizzi, A. 2007. Veiling glare: the dynamic range limit of HDR images. In Human Vision and Electronic Imaging XII, SPIE, vol. 6492.Google ScholarGoogle Scholar
  11. Nayar, S. K., and Branzoi, V. 2003. Adaptive dynamic range imaging: Optical control of pixel exposures over space and time. In IEEE International Conference on Computer Vision, 1168--1175. Google ScholarGoogle ScholarDigital LibraryDigital Library
  12. Nayar, S. K., Krishnan, G., Grossberg, M. D., and Raskar, R. 2006. Fast separation of direct and global components of a scene using high frequency illumination. In ACM Transactions on Graphics, ACM Press, New York, NY, USA, 935--944. Google ScholarGoogle ScholarDigital LibraryDigital Library
  13. Reinhard, E., Ward, G., Pattanaik, S., and Debevec, P. 2006. High Dynamic Range Imaging - Acquisition, Display and Image-based Lighting. Morgan Kaufman Publishers, 500 San-some Street, Suite 400, San Francisco, CA 94111. Google ScholarGoogle ScholarDigital LibraryDigital Library
  14. Seibert, J. A., Nalcioglu, O., and Roeck, W. 1985. Removal of image intensifier veiling glare by mathematical deconvolution techniques. Medical physics 12, 3, 281--288.Google ScholarGoogle Scholar
  15. Sen, P., Chen, B., Garg, G., Marschner, S. R., Horowitz, M., Levoy, M., and Lensch, H. P. A. 2005. Dual photography. In ACM Transactions on Graphics, ACM Press, New York, NY, USA, 745--755. Google ScholarGoogle ScholarDigital LibraryDigital Library
  16. Starck, J., Pantin, E., and Murtagh, F. 2002. Deconvolution in astronomy: A review. Publications of the Astronomical Society of the Pacific 114, 1051--1069.Google ScholarGoogle ScholarCross RefCross Ref
  17. Wilburn, B., Joshi, N., Vaish, V., Talvala, E.-V., Antunez, E., Barth, A., Adams, A., Horowitz, M., and Levoy, M. 2005. High performance imaging using large camera arrays. In ACM Transactions on Graphics, ACM Press, New York, NY, USA, 765--776. Google ScholarGoogle ScholarDigital LibraryDigital Library

Recommendations