ABSTRACT
The realization of a prototype for a novel band-selective personal exposure assessment system is presented. The new system combines three features that are crucial for Non-Ionising-Radiation (NIR) monitoring, namely the measurement of power levels of selected near field sources, e.g. internal Wi-Fi module, field levels of far field sources and global position measurements. For this, it uses the features of a common smartphone by an additional software application and an external exposimeter module. The system can be either used for environmental monitoring of field levels or used in future epidemiological studies. Such an approach has the potential for huge NIR studies, featuring representative results with a higher measurement accuracy and an increased functionality compared to current systems.
- Android; website:http://www.android.com/.Google Scholar
- Cassiopea project; website:http://www.stroud.gov.uk/docs/cassiopea/cassiopea.asp.Google Scholar
- P. Frei et al. Temporal and spatial variability of personal exposure to radio frequency electromagnetic fields. Environ Res, 109:779--785, 2009.Google ScholarCross Ref
- K. Radon et al. An epidemiologic feasibility study comparing the maschek dosimeter prototype and the antennessa sp-090 system. Bioelectromagnetics., 27(1):77--81, 2006.Google ScholarCross Ref
Index Terms
- Poster: A novel measurement system for environmental exposure monitoring
Recommendations
Hydrogel fluorescent sensor for long term environmental measurement
2017 International Symposium on Micro-NanoMechatronics and Human Science (MHS)Long-term environment measurement by hydrogel fluorescence sensor using fluorescence recovery after photobleaching (FRAP) was developed. Photobleaching of fluorescence sensor is compensated by FRAP in the fluorescence sensor made of low concentration of ...
Poster: Coordination of Wireless Sensor Networks using Visible Light
SenSys '15: Proceedings of the 13th ACM Conference on Embedded Networked Sensor SystemsWireless sensor networks are often deployed indoors where artificial lighting is present. Indoor lighting is increasingly being composed of Light Emitting Diodes (LEDs) that offer the ability to precisely control the intensity and the frequency of the ...
Electric Field Measurement for Biomedical Application -- Characteristics of Raw Measurement Data
ICBEB '12: Proceedings of the 2012 International Conference on Biomedical Engineering and BiotechnologyThe authors are studying a technique to measure moisture distribution inside the human body by applying electric field at radio frequency (RF). Weak RF power is fed to an antenna that is as small as a few centimeters square, and the same type of antenna ...