skip to main content
10.1145/2093698.2093731acmotherconferencesArticle/Chapter ViewAbstractPublication PagesisabelConference Proceedingsconference-collections
research-article

Respiration monitoring during sleeping

Published: 26 October 2011 Publication History

Abstract

The respiration belongs among basic vital functions and the knowledge of their parameters and quality is necessary in medicine. The research is leading to the methods, which are inconvenienced patients. These methods are important for monitoring respiration towards observation quality sleeping or The Sudden Infant Death Syndrome (SIDS). This paper contains an overview of the methods for the respiration monitoring used not only in practice of medicine but till now developed.

References

[1]
J. Rozman, Electronic equipment in medicine, Elektronické přístroje v lékařství, Academia, Praha 2006, ISBN 80-200-1308-3.
[2]
J. D. Bronzino, The Biomedical Engineering HandBook, Second Edition, CRC Press LLC, ISBN 0-8493-0461-X.
[3]
H. Aoki, K. Koshiji, "Non-contact Respiration Monitoring Method for Screening Sleep Respiratory Disturbance Using Slit Light Pattern Projection", World Congress on Medical Physics and Biomedical Engineering 2006 IFMBE
[4]
Proceedings, 2007, Volume 14, Part 7, p. 680--683.
[5]
M. Uenoyama, T. Matsui, K. Yamada, "Non-contact respiratory monitoring system using a ceiling-attached microwave antena", Medical and Biological Engineering and Computing Volume 44, Number 9, 2006, p. 835--840.
[6]
K. M. Chen, Y. Huang, J. Zhang, "Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier", IEEE Trans Biomed Eng 27:105--113.
[7]
M. Ishijima, "Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored", Med. Biol. Eng. Comput., 1997, 35, p. 685--69.
[8]
P. Hult, B. Wranne, P. Ask, "A bioacoustic method for timing of the different phases of the breathing cycle and monitoring of breathing frequency", Medical Engineering & Physics 22 (2000) 425--433.
[9]
J. Kroutil, M. Husak, "Detection of Breathing", In ASDAM 2008 Conference Proceedings. Bratislava: Slovak University of Technology, 2008, vol. 1, p. 167--170. ISBN 978-1-4244-2325-5.
[10]
A. S. Sezen, S. Sivaramakrishnan, S. Hur, R. Rajamani, W. Robbins, B. J. Nelson, "Passive Wireless MEMS Microphones for Biomedical pplications", Journal of Biomechanical Engineering, Vol.127, Iss.6, pp.1030, 2005, ISSN: 01480731.
[11]
Ballantine D. S., White R. M., Martin S. J., Ricco A. J., Frye G. C., Zellers E. T., and Wohltjen H., Acoustic Wave Sensors: Theory, Design, and Physico-Chemical Applications, New York: Academic Press, 1997.

Cited By

View all
  • (2016)SpiroCallProceedings of the 2016 CHI Conference on Human Factors in Computing Systems10.1145/2858036.2858401(5675-5685)Online publication date: 7-May-2016
  • (2015)Vision-based patient monitoring: a comprehensive review of algorithms and technologiesJournal of Ambient Intelligence and Humanized Computing10.1007/s12652-015-0328-19:2(225-251)Online publication date: 26-Nov-2015
  • (2012)SpiroSmartProceedings of the 2012 ACM Conference on Ubiquitous Computing10.1145/2370216.2370261(280-289)Online publication date: 5-Sep-2012

Recommendations

Comments

Information & Contributors

Information

Published In

cover image ACM Other conferences
ISABEL '11: Proceedings of the 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies
October 2011
949 pages
ISBN:9781450309134
DOI:10.1145/2093698
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

Sponsors

  • Universitat Pompeu Fabra
  • IEEE
  • Technical University of Catalonia Spain: Technical University of Catalonia (UPC), Spain
  • River Publishers: River Publishers
  • CTTC: Technological Center for Telecommunications of Catalonia
  • CTIF: Kyranova Ltd, Center for TeleInFrastruktur

Publisher

Association for Computing Machinery

New York, NY, United States

Publication History

Published: 26 October 2011

Permissions

Request permissions for this article.

Check for updates

Author Tags

  1. MEMS
  2. SAW
  3. biological signal
  4. biomedical sensors
  5. respiration

Qualifiers

  • Research-article

Funding Sources

Conference

ISABEL '11
Sponsor:
  • Technical University of Catalonia Spain
  • River Publishers
  • CTTC
  • CTIF

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • Downloads (Last 12 months)1
  • Downloads (Last 6 weeks)0
Reflects downloads up to 10 Feb 2025

Other Metrics

Citations

Cited By

View all
  • (2016)SpiroCallProceedings of the 2016 CHI Conference on Human Factors in Computing Systems10.1145/2858036.2858401(5675-5685)Online publication date: 7-May-2016
  • (2015)Vision-based patient monitoring: a comprehensive review of algorithms and technologiesJournal of Ambient Intelligence and Humanized Computing10.1007/s12652-015-0328-19:2(225-251)Online publication date: 26-Nov-2015
  • (2012)SpiroSmartProceedings of the 2012 ACM Conference on Ubiquitous Computing10.1145/2370216.2370261(280-289)Online publication date: 5-Sep-2012