skip to main content
10.1145/3163080.3163123acmotherconferencesArticle/Chapter ViewAbstractPublication PagesicspsConference Proceedingsconference-collections
research-article

Smart portable system for protein concentration detection

Published:27 November 2017Publication History

ABSTRACT

Since proteins can be the biomarkers of the human disease, a rapid, convenient detection device for protein detection is worthy of research and development. In this paper, a low power and portable system for protein concentration detection system with a biosensor based on alternating current impedance measurement technique is presented. The biosensor is implemented by printed metal electrodes form to enhance the linearity of the system and a calibration circuitry is applied to ensure the high resolution of the identification and calibrate the biosensor when replaced for measuring. The proposed system can provide a rapid and high sensitive detection in 10 seconds. The measurement result demonstrated a high sensitivity of the implemented system which could be capable of detecting bull serum albumin (BSA) and thrombin as low as 4.03 μg/ml and 8.06 ng/ml, respectively. The whole power consumption of the implemented system is 22.3 mW with a supply voltage of 3 V and consumes a current of 10 μA when working in idle mode.

References

  1. Abdulsalam Yassine, Shailendra Singh, Atif Alamri. 2017. Mining Human Activity Patterns from Smart Home Big Data for Health Care Applications. IEEE Access. 5. 13131--13141.Google ScholarGoogle Scholar
  2. V. G. Koutkias, I. Chouvarda, N. Maglaveras. 2005. A multiagent system enhancing home-care health services for chronic disease management. Trans. on Information Technology in Biomedicin. 9, 4 (Dec. 2005), 528--537. Google ScholarGoogle ScholarDigital LibraryDigital Library
  3. Xiaoyi Lv,Liping Xin, Guodong Lv, et al. 2017. Preparation of a Photoluminescent Film on a Silicon-On-Insulator Device for the Simple, Rapid, and Quantitative Detection of a Hydatid Disease Diagnostic Protein Marker. Photonics Journal. 9, 4 (Aug. 2017).Google ScholarGoogle Scholar
  4. Gui-Min Qin, Rui-Yi Li, Xing-Ming Zhao. 2016. Identifying Disease Associated miRNAs Based on Protein Domains. Trans. on Computational Biology and Bioinformatics. 13, 6 (Jan. 2016), 1027--1035. Google ScholarGoogle ScholarDigital LibraryDigital Library
  5. O. Tokel, F. Inci, U. Demirci.2014. Advances in plasmonic technologies for point of care applications. J.Chem. Rev. 114 (2014) 5728--5752.Google ScholarGoogle ScholarCross RefCross Ref
  6. Jahwarhar Izuan Abd Rashid, Nor Azah Yusof, Jaafar Abdullah, et al. 2015. A Novel Disposable Biosensor Based on SiNWs/AuNPs Modified-Screen Printed Electrode for Dengue Virus DNA Oligomer Detection. IEEE Sensors Journal. 15, 8 (Aug. 2015), 4420--4427.Google ScholarGoogle Scholar
  7. Irina Mirela Apetrei, Constantin Apetrei. 2015. Study of Different Carbonaceous Materials as Modifiers of Screen-Printed Electrodes for Detection of Catecholamines. IEEE Sensors Journal. 15, 6(June 2015), 3094--3101.Google ScholarGoogle ScholarCross RefCross Ref
  8. C.D. Chin, V. Linder, S.K. Sia. 2012. Commercialization of microfluidic point-of-care diagnostic devices. Lab Chip. 12 (2012), 2118--2134.Google ScholarGoogle ScholarCross RefCross Ref
  9. Y. Huang, M. Shi, K. Hu, S. Zhao, X. Lu, Z.-F. Chen, et al. 2013. Carbon nanotube-based multicolor fluorescent peptide probes for highly sensitive multiplex detection of cancer-related proteases. J. Mater. Chem. B. 1 (2013) 3470--3476.Google ScholarGoogle ScholarCross RefCross Ref
  10. X. Liu, T.-Y. Lin, P.B. Lillehoj. 2014. Smartphones for cell and biomolecular detection. Annals of Biomedical Engineering. 42, 11 (November 2014), 2205--2217.Google ScholarGoogle ScholarCross RefCross Ref
  11. Agnes Grünerbl, Amir Muaremi, Venet Osmani, et al. 2015. Smartphone-Based Recognition of States and State Changes in Bipolar Disorder Patients. J.of Biomedical and Health Informatics. 19, 1 (Jan. 2015), 140--148.Google ScholarGoogle ScholarCross RefCross Ref
  12. D. Panescu, J. G. Webster, R. A. Stratbucker. 1994. A nonlinear finite element model of the electrode-electrolyte-skin system. Trans. on Biomedical Engineering, 41,7 (July 1994), 681--687Google ScholarGoogle ScholarCross RefCross Ref
  13. Chen YP, Xianyu YL, Jiang XY. 2017. Surface modification of gold nanoparticles with small molecules for biochemical analysis. Accounts Chem. Re. 50, 2 (Jan. 2017), 310--319.Google ScholarGoogle Scholar
  14. Donghai Li, Xiang Ruan; Qiang Xu, Kebin Wang, et al. 2002. Heat denaturation of protein structures and chlorophyll states in PSII membranes. Tsinghua Science and Technology, 7, 4 (Aug. 2002), 407--410.Google ScholarGoogle Scholar

Index Terms

  1. Smart portable system for protein concentration detection

    Recommendations

    Comments

    Login options

    Check if you have access through your login credentials or your institution to get full access on this article.

    Sign in
    • Published in

      cover image ACM Other conferences
      ICSPS 2017: Proceedings of the 9th International Conference on Signal Processing Systems
      November 2017
      237 pages
      ISBN:9781450353847
      DOI:10.1145/3163080

      Copyright © 2017 ACM

      Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

      Publisher

      Association for Computing Machinery

      New York, NY, United States

      Publication History

      • Published: 27 November 2017

      Permissions

      Request permissions about this article.

      Request Permissions

      Check for updates

      Qualifiers

      • research-article
      • Research
      • Refereed limited

      Acceptance Rates

      Overall Acceptance Rate46of83submissions,55%

    PDF Format

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader