skip to main content
10.1145/3173574.3173999acmconferencesArticle/Chapter ViewAbstractPublication PageschiConference Proceedingsconference-collections
research-article
Honorable Mention

Seismo: Blood Pressure Monitoring using Built-in Smartphone Accelerometer and Camera

Published:21 April 2018Publication History

ABSTRACT

Although cost-effective at-home blood pressure monitors are available, a complementary mobile solution can ease the burden of measuring BP at critical points throughout the day. In this work, we developed and evaluated a smartphone-based BP monitoring application called textitSeismo. The technique relies on measuring the time between the opening of the aortic valve and the pulse later reaching a periphery arterial site. It uses the smartphone's accelerometer to measure the vibration caused by the heart valve movements and the smartphone's camera to measure the pulse at the fingertip. The system was evaluated in a nine participant longitudinal BP perturbation study. Each participant participated in four sessions that involved stationary biking at multiple intensities. The Pearson correlation coefficient of the blood pressure estimation across participants is 0.20-0.77 ($mu$=0.55, $sigma$=0.19), with an RMSE of 3.3-9.2 mmHg ($mu$=5.2, $sigma$=2.0).

Skip Supplemental Material Section

Supplemental Material

pn3572-file3.mp4

mp4

18 MB

pn3572-file5.mp4

mp4

14 MB

References

  1. Rajiv Agarwal, Jennifer E. Bills, Tyler J.W. Hecht, and Robert P. Light. 2010. Role of Home Blood Pressure Monitoring in Overcoming Therapeutic Inertia and Improving Hypertension Control. Hypertension 57, 1 (2010), 29--38.Google ScholarGoogle ScholarCross RefCross Ref
  2. A Bernjak and A Stefanovska. 2009. Pulse transit times to the capillary bed evaluated by laser Doppler flowmetry. (Mar 2009). https://www.ncbi.nlm.nih.gov/pubmed/19202235Google ScholarGoogle Scholar
  3. Andrew M. Carek, Jordan Conant, Anirudh Joshi, Hyolim Kang, and Omer T. Inan. 2017. SeismoWatch: Wearable Cuffless Blood Pressure Monitoring Using Pulse Transit Time. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 1, 3, Article 40 (Sept. 2017), 16 pages. Google ScholarGoogle ScholarDigital LibraryDigital Library
  4. V. Chandrasekaran, R. Dantu, S. Jonnada, S. Thiyagaraja, and K. P. Subbu. 2013. Cuffless Differential Blood Pressure Estimation Using Smart Phones. IEEE Transactions on Biomedical Engineering 60, 4 (April 2013), 1080--1089.Google ScholarGoogle ScholarCross RefCross Ref
  5. G. Fortino and V. Giampa. 2010. PPG-based methods for non invasive and continuous blood pressure measurement: an overview and development issues in body sensor networks. In IEEE International Workshop on Medical Measurements and Applications. 10--13.Google ScholarGoogle Scholar
  6. Christian Holz and Edward J. Wang. 2017. Glabella: Continuously Sensing Blood Pressure Behavior Using an Unobtrusive Wearable Device. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 1, 3, Article 58 (Sept. 2017), 23 pages. Google ScholarGoogle ScholarDigital LibraryDigital Library
  7. O. T. Inan, P. F. Migeotte, K. S. Park, M. Etemadi, K. Tavakolian, R. Casanella, J. Zanetti, J. Tank, I. Funtova, G. K. Prisk, and M. Di Rienzo. 2015. Ballistocardiography and Seismocardiography: A Review of Recent Advances. IEEE Journal of Biomedical and Health Informatics 19, 4 (July 2015), 1414--1427.Google ScholarGoogle ScholarCross RefCross Ref
  8. A.Dias Junior, Srinivasan Murali, Francisco Rincon, and David Atienza. 2015. Estimation of blood pressure and pulse transit time using your smartphone. In Euromicro Conference on Digital System Design (DSD). 173--180. Google ScholarGoogle ScholarDigital LibraryDigital Library
  9. M. Kachuee, M. M. Kiani, H. Mohammadzade, and M. Shabany. 2015. Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. In International Symposium on Circuits and Systems (ISCAS). 1006--1009.Google ScholarGoogle Scholar
  10. Chang-Sei Kim, Andrew M. Carek, Ramakrishna Mukkamala, Omer T. Inan, and Jin-Oh Hahn. 2015. Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring. IEEE transactions on bio-medical engineering (Nov 2015). https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4626385/Google ScholarGoogle Scholar
  11. F. Landreani, M. Morri, A. Martin-Yebra, C. Casellato, E. Pavan, C. Frigo, and E. G. Caiani. 2017. Ultra-short-term heart rate variability analysis on accelerometric signals from mobile phone. In E-Health and Bioengineering Conference (EHB). 241--244.Google ScholarGoogle Scholar
  12. J D Lane, L Greenstadt, D Shapiro, and E Rubinstein. 1983. Pulse transit time and blood pressure: an intensive analysis. Psychophysiology. (Jan 1983). https://www.ncbi.nlm.nih.gov/pubmed/6828611Google ScholarGoogle Scholar
  13. He Liu, Kamen Ivanov, Yadong Wang, and Lei Wang. 2015. Toward a Smartphone Application for Estimation of Pulse Transit Time. In Sensors.Google ScholarGoogle Scholar
  14. G V Marie, C R Lo, J Van, and D W Johnston. 1984. The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise. Psychophysiology. (Sep 1984). https://www.ncbi.nlm.nih.gov/pubmed/6473621Google ScholarGoogle Scholar
  15. Reham Mohamed and Moustafa Youssef. 2017. HeartSense: Ubiquitous Accurate Multi-Modal Fusion-based Heart Rate Estimation Using Smartphones. IMWUT 1 (2017), 97:1--97:18. Google ScholarGoogle ScholarDigital LibraryDigital Library
  16. R. Mukkamala, J. O. Hahn, O. T. Inan, L. K. Mestha, C. S. Kim, H. TÃűreyin, and S. Kyal. 2015. Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice. IEEE Transactions on Biomedical Engineering 62, 8 (Aug 2015), 1879--1901.Google ScholarGoogle ScholarCross RefCross Ref
  17. Andreas Patzak, Yuri Mendoza, Heiko Gesche, and Martin Konermann. 2015. Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement. Blood pressure 24, 4 (April 2015), 217--221.Google ScholarGoogle Scholar
  18. Rong-Chao Peng, Wen-Rong Yan, Ning-Ling Zhang, Wan-Hua Lin, Xiao-Lin Zhou, and Yuan-Ting Zhang. 2015. Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals. Sensors 15, 9 (2015), 23653S23666.Google ScholarGoogle Scholar
  19. Carla Sala, Erika Santin, Marta Rescaldani, Cesare Cuspidi, and Fabio Magrini. 2005. What is the accuracy of clinic blood pressure measurement? American Journal of Hypertension 18, 2 (2005), 244--248.Google ScholarGoogle ScholarCross RefCross Ref
  20. J. Talts, R. Raamat, K. Jagomägi, and J. Kivastik. 2011. An Influence of Multiple Affecting Factors on Characteristic Ratios of Oscillometric Blood Pressure Measurement. Springer Berlin Heidelberg, Berlin, Heidelberg, 73--76.Google ScholarGoogle Scholar
  21. WHO. 2017. Global Health Observatory (GHO) data: Raised blood pressure. (2017). Retrieved May 30, 2017 from http://www.who.int/gho/ncd/risk_factors/blood_pressure_prevalence_text/en/Google ScholarGoogle Scholar
  22. E. S. Winokur, D. D. He, and C. G. Sodini. 2012. A wearable vital signs monitor at the ear for continuous heart rate and Pulse Transit Time measurements. In Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2724--2727.Google ScholarGoogle Scholar
  23. Mico Yee-Man Wong, Carmen Chung-Yan Poon, and Yuan-Ting Zhang. 2009. An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects. Cardiovascular Engineering 9, 1 (01 Mar 2009), 32--38.Google ScholarGoogle Scholar
  24. C. Yang and N. Tavassolian. 2017. Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison. IEEE Journal of Biomedical and Health Informatics PP, 99 (2017), 1--1.Google ScholarGoogle Scholar
  25. Guanqun Zhang, Mingwu Gao, Da Xu, N. Bari Olivier, and Ramakrishna Mukkamala. 2011a. Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. Journal of Applied Physiology 111, 6 (2011), 1681--1686.Google ScholarGoogle ScholarCross RefCross Ref
  26. Y L Zhang, Y Y Zheng, Z C Ma, and Y N Sun. 2011b. Radial pulse transit time is an index of arterial stiffness. Hypertension research : official journal of the Japanese Society of Hypertension. (Jul 2011). https://www.ncbi.nlm.nih.gov/pubmed/21593741Google ScholarGoogle Scholar

Index Terms

  1. Seismo: Blood Pressure Monitoring using Built-in Smartphone Accelerometer and Camera

    Recommendations

    Comments

    Login options

    Check if you have access through your login credentials or your institution to get full access on this article.

    Sign in
    • Published in

      cover image ACM Conferences
      CHI '18: Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems
      April 2018
      8489 pages
      ISBN:9781450356206
      DOI:10.1145/3173574

      Copyright © 2018 ACM

      Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

      Publisher

      Association for Computing Machinery

      New York, NY, United States

      Publication History

      • Published: 21 April 2018

      Permissions

      Request permissions about this article.

      Request Permissions

      Check for updates

      Qualifiers

      • research-article

      Acceptance Rates

      CHI '18 Paper Acceptance Rate666of2,590submissions,26%Overall Acceptance Rate6,199of26,314submissions,24%

    PDF Format

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader