Integration of building interface and smart sensor network to control indoor air pollution through internet of things

Authors Info & Claims
Published:16 March 2019Publication History

ABSTRACT

The interior environment of Taiwan has been affected by interior air pollution for a long time. It would affect our health and comfort directly, and it also affects our efficiency of work and study. Especially for Formaldehyde, VOCs and particle etc., those contaminations would be changed by the environmental factor easily. This study is focusing on analyzing the relationship between contamination resources and removable contamination, then we can get to understand the connection between cleansing airs and different kinds of interface management of construction. This study uses the IoT connecting system and full-scale space to analyze different factors indoor in order to collect big data. It can clarify the most influential factor for the intervening variable of different management of construction project throughout the statistics of the big data, and make the result to be one of the determent analyzing assessment mode. The study result builds the "SIPETs" throughout the "platform of smart sensing and data analyzing". It can monitor the condition of contamination distributing indoor, and control the air flowing, air cleansing, energy saving and peristome shifting etc., and maintain the benefit of interior comfort and saving energy. Building this system helps us improve those existing buildings to adjust itself for facing climate changing. And it also can protect people who live inside and maintain comfort and reduce the value at risk.

References

  1. Smart sensor technology to combat indoor air pollution, IAQSENSE - Nanotechnology based gas multispectral sensing system for environmental control and protection, European Commission Community Research and Development Information Service. (2013)Google ScholarGoogle Scholar
  2. European Network on New Sensing Technologies for Air-Pollution Control and Environmental Sustainability-EuNetAir, European Commission Community Research and Development Information Service. (2013)Google ScholarGoogle Scholar
  3. Freijer JI, Bloemen HJ.: Modeling relationships between indoor and outdoor air quality. J Air Waste Manag Assoc. (2000) Feb;50(2):P.292--300Google ScholarGoogle Scholar
  4. Sakr W, Weschler CJ, Fanger PO.: The impact of sorption on perceived indoor air quality., Indoor Air (2006).16(2) P.98--110.Google ScholarGoogle Scholar
  5. ISO-16000-10 Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing-Emission Test Cell (2006)Google ScholarGoogle Scholar
  6. Bucakova, M., and I. Senitkova, Building Material Interactions and Perceived Air Quality, Proceedings of Clima WellBeing Indoors(2007)Google ScholarGoogle Scholar
  7. ISO-16000-3 Indoor air - Part 3: Determination of formaldehyde andother carbonyl compounds - Active sampling method, (2001)Google ScholarGoogle Scholar
  8. ISO-16000-4 Indoor air - Part 4: Determination of formaldehyde -Diffusive sampling method, (2004)Google ScholarGoogle Scholar
  9. ISO-16000-6 Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID, (2004)Google ScholarGoogle Scholar
  10. Singer, B. C., Sorption of organic gases in a furnished room, Atmospheric Environment 38 pp. 2483--2494 (2004)Google ScholarGoogle ScholarCross RefCross Ref
  11. J Matsumoto, S Tanabe and R Aoki, DEVELOPMENT OF MEASUREMENT DEVICE (ADSEC) FOR ALDEHYDES AND VOCS EMISSION RATES USING A DIFFUSIVE SAMPLER.,Indoor Air,2002.Google ScholarGoogle Scholar
  12. S Murakami, S Kato, Q Zhu, K Ito, 3D-CFD ANALYSIS OF DIFFUSION AND EMISSION OF VOCs IN A FLEC CAVITY.,Indoor Air,(2002).Google ScholarGoogle Scholar
  13. Shuzo Murakami, Shinsuke Kato,Kazuhide Ito,Tatsuya Hayashi,CFD ANALYSIS OF INDOOR CHEMICAL ENVIRONMENT AND INHALED CONTAMINANT BY A HUMAN BODY. Indoor Air, (2002).Google ScholarGoogle Scholar

Index Terms

  1. Integration of building interface and smart sensor network to control indoor air pollution through internet of things

    Recommendations

    Comments

    Login options

    Check if you have access through your login credentials or your institution to get full access on this article.

    Sign in
    • Published in

      cover image ACM Other conferences
      IEEA '19: Proceedings of the 8th International Conference on Informatics, Environment, Energy and Applications
      March 2019
      281 pages
      ISBN:9781450361040
      DOI:10.1145/3323716

      Copyright © 2019 ACM

      Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

      Publisher

      Association for Computing Machinery

      New York, NY, United States

      Publication History

      • Published: 16 March 2019

      Permissions

      Request permissions about this article.

      Request Permissions

      Check for updates

      Qualifiers

      • research-article
    • Article Metrics

      • Downloads (Last 12 months)26
      • Downloads (Last 6 weeks)8

      Other Metrics

    PDF Format

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader