Experimental Study on Bone Health in Drilling

Authors Info & Claims
Published:28 March 2019Publication History

ABSTRACT

Drilling in bone is a common surgical procedure routinely performed in orthopedics and dental surgeries for repair and fixation purposes. Measurement and control of bone temperature and drilling thrust force are critical to the outcome of the procedure. Excessive heat and large drilling force and torque produce in bone drilling process may cause physiological changes in the bone cells. The aim of this study was to evaluate the extent of biological damage in the immediate vicinity of the drilling region. Temperature in bone drilling process was measured by varying drill speed. The effect of bone temperature on the extent of cells damage surrounding the drilling area was evaluated. Necrotic depth was measured for the range of temperatures obtained from drilling experiments. Elevated temperature in bone was found to have negative impact on the health of the bone. Result showed that minimum cell damage can be achieved by using lower drill speed in bone drilling operation.

References

  1. Alam, K., Mitrofanov, A. V., and Silberschmidt, V. V. 2011. Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone. Med. Eng. Phys. 33(2), 234--239.Google ScholarGoogle ScholarCross RefCross Ref
  2. Lee, J., Ozdoganlar, O. B., and Rabin, Y. 2012. An experimental investigation on thermal exposure during bone drilling. Med. Eng. Phys. 34, 1510--1520.Google ScholarGoogle ScholarCross RefCross Ref
  3. Sezek, S., Aksakal, B., and Karaca, F. 2012. Influence of drill parameters on bone temperature and necrosis: A FEM modelling and in vitro experiments. Comput. Mater. Sci, 60, 13--18.Google ScholarGoogle ScholarCross RefCross Ref
  4. Alam, K., Kham, M., and Silberschmidt, V. V. 2014. 3D Finite Element modelling of drilling cortical bone: Temperature Analysis. J. Med. Biolog. Eng. 34(6), 618--623.Google ScholarGoogle Scholar
  5. Hillery, H. T., and Shuaib, I. 1999. Temperature effects in the drilling of human and bovine bone. J. Mater. Process. Technol. 92-93, 302--308.Google ScholarGoogle ScholarCross RefCross Ref
  6. Bachus, K. N., Rondina, M. T., and Hutchinson, D. T. 2000. The effects of drilling force on cortical temperatures and their duration: an in vitro study. Med. Eng. Phys. 22, 685--691.Google ScholarGoogle ScholarCross RefCross Ref
  7. Davidson, S.R.H., and James, D. F. 2003. Drilling in bone: modeling heat generation and temperature distribution. J. Biomech. Eng.-Trans. ASME. 125, 305--314.Google ScholarGoogle ScholarCross RefCross Ref
  8. Pandey, R. K., and Panda, S. S. 2013. Drilling of bone: A comprehensive review. J. Clin. Orthop. Trauma. 4, 15--30.Google ScholarGoogle ScholarCross RefCross Ref
  9. Augustin, G., Zigman, T., Davila, S., Udilljak, T., Staroveski, T., Brezak, D., and Babic, S. 2012. Cortical bone drilling and thermal osteonecrosis. Clin. Biomech. 27, 313--325.Google ScholarGoogle ScholarCross RefCross Ref
  10. Lee, J., Gozen, B. A., Ozdoganlar, O. B. 2012. Modeling and experimentation of bone drilling forces. J. Biomech. 45(6), 1076--1083.Google ScholarGoogle ScholarCross RefCross Ref
  11. Pallan, F. G. 1960. Histological change in bone after insertion of skeletal fixation pins. J. Oral. Surg. Anest. Hosp. Dent. Serv.18, 400--408.Google ScholarGoogle Scholar
  12. Eriksson R. A., Albrektsson T., and Magnusson, B. 1984. Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit. Scand. J. Plast. Reconstr. Surg. 18, 261--268.Google ScholarGoogle ScholarCross RefCross Ref
  13. Lundskog J. 1972. Heat and bone tissue. Scand. J. Plast. Reconstr. Surg. Suppl. 9, 1--80.Google ScholarGoogle Scholar
  14. Berman, A. T., Reid, J. S, Yanicko, D. R Jr, Sih, G. C., and Zimmerman, M. R. 1984. Thermally induced bone necrosis in rabbits. Relation to implant failure in humans. Clin. Orthop. Relat. Res. Jun. 186, 284--92.Google ScholarGoogle ScholarCross RefCross Ref
  15. Franssen, B. B, Van Diest, P. J., Schuurman A. H., and Kon, M. 2008. Drilling K-wires, what about the osteocytes? An experimental study in rabbits. Arch. Orthop. Trauma. Surg. 2008. 128(1), 83--87.Google ScholarGoogle Scholar
  16. Chen, H., Sun, J., Hoemann, C. D., Lascau-Coman, V., Ouyang,W., McKee M. D., Shive, M. S., and Buschmann, M. D. 2009. Drilling and microfracture lead to different bone structure and necrosis during bone-marrow stimulation for cartilage repair. J. Orthop. Res. 27(11), 1432--1438.Google ScholarGoogle ScholarCross RefCross Ref
  17. Franssen, B. B., Van Diest, P. J., Schuurman, A. H., and Kon, M. 2008. Keeping osteocytes alive: a comparison of drilling and hammering K-wires into bone. J. Hand. Surg-Eur. 33(3), 363--368.Google ScholarGoogle ScholarCross RefCross Ref
  18. James, T. P., Chang, G., Micucci, S., Sagar, A., Smith, E. L., and Cassidy, C. 2014. Effect of applied force and blade speed on histopathology of bone during resection by sagittal saw. Med. Eng. Phys. 36(3), 364--370.Google ScholarGoogle ScholarCross RefCross Ref
  19. Hou, Y., Changhe, Li., Hongliang, Ma., Zhang, Y., Yang, M., and Zhang, X. 2015. An experimental research on bone drilling temperature in orthopaedic surgery. The. Open. Mat. Sci. 9, 178--188.Google ScholarGoogle ScholarCross RefCross Ref
  20. Thompson, H. C. 1958. Effect of drilling into bone. J. Oral. Surg. (Chic).16(1), 22--30.Google ScholarGoogle Scholar
  21. Vaughn, R. C., and Peyton, F. A. 1951. The influence of rotational speed on temperature rise during cavity preparation. J. Dent. Res. 30(5), 737--44.Google ScholarGoogle ScholarCross RefCross Ref
  22. Abouzgia, M. B., Symington, J. M. 1996. Effect of drill speed on bone temperature. Int. J. Oral Maxillof. Surg. 25(5), 394--399.Google ScholarGoogle ScholarCross RefCross Ref
  23. Matthews, L. S., and Hirsch, C. 1972. Temperatures measured in human cortical bone when drilling. J. Bone. Joint. Surg. Am. 54, 297--308.Google ScholarGoogle ScholarCross RefCross Ref

Index Terms

  1. Experimental Study on Bone Health in Drilling

    Recommendations

    Comments

    Login options

    Check if you have access through your login credentials or your institution to get full access on this article.

    Sign in
    • Published in

      cover image ACM Other conferences
      ICBET '19: Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology
      March 2019
      327 pages
      ISBN:9781450361309
      DOI:10.1145/3326172

      Copyright © 2019 ACM

      Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

      Publisher

      Association for Computing Machinery

      New York, NY, United States

      Publication History

      • Published: 28 March 2019

      Permissions

      Request permissions about this article.

      Request Permissions

      Check for updates

      Qualifiers

      • research-article
      • Research
      • Refereed limited
    • Article Metrics

      • Downloads (Last 12 months)1
      • Downloads (Last 6 weeks)0

      Other Metrics

    PDF Format

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader