Z-range Extension of Volume Imaged with Clinical C-arm Computed Tomography from A Single Rotation Helical Cone-beam Scan

Published: 24 August 2019 Publication History

Abstract

In conventional computed tomography (CT) imaging, cone-beam (CB) projection data generated with a helical scanning trajectory (namely helical CB scan) are complete for an exact analytic reconstruction according to data sufficiency condition (DSC). As for clinical C-arm CT imaging, a helical CB scanning is intuitively useful for extending the z-range of volume to be imaged effectively, which is equivalent to the reduction of total dose delivered to patient as compared with conventional circular CB scanning. Nevertheless, this z-range extension of imaged volume is relatively limited, since at most a single rotation is available for clinical C-arm CT imaging. Meanwhile, only approximate CB-FBP reconstruction algorithm is feasible for this task by relaxing the requirement on the exactness of image reconstruction. It has been well known that, using the conventional helical CB-FBP reconstruction algorithm, the severe CB artifacts are observable, especially within the outer slices, while extending the z-range of imaged volume. To effectively suppress these CB artifacts within the outer slices, in this work a three-dimensional (3D) weighted helical CB-FBP reconstruction algorithm is proposed for specifically improving the image quality in the extended z-range. Using the digitalized patient data simulated by computer with the geometrical parameters of an actual C-arm CT imaging system, we conduct an initial study to investigate the performance of the proposed algorithm. The preliminary results show that the proposed algorithm does improve the image quality for clinical C-arm CT imaging with a single rotation helical CB scan.

References

[1]
Kudo, H., Noo, F., and Defrise, M. 1998. Cone-beam filtered-backprojection algorithm for truncated helical data. Phys. Med. Biol. 43, 10 (1998), 2885--2909. DOI= https://doi.org/10.1088/0031-9155/43/10/016
[2]
Defrise, M., Noo, F., and Kudo, H. 2000. A solution to the long-object problem in helical cone-beam tomography. Phys. Med. Biol. 45, 3 (2000), 623--643. DOI= https://doi.org/10.1088/0031-9155/45/3/305
[3]
Katsevich, A. 2002. Analysis of an exact inversion algorithm for spiral cone-beam CT. Phys. Med. Biol. 47, 15 (2002), 2583--2597. DOI= https://doi.org/10.1088/0031-9155/47/15/302
[4]
Zou, Y. and Pan, X. 2004. Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT. Phys. Med. Biol. 49, 6 (2004), 941--959. DOI= https://doi.org/10.1088/0031-9155/49/6/006
[5]
Tang, X. and Hsieh, J. 2004. A filtered backprojection algorithm for cone beam reconstruction using rotational filtering under helical source trajectory. Med. Phys. 31, 11 (2004), 2949--2960. DOI= https://doi.org/10.1118/1.1803672
[6]
Tang, X., Hsieh, J., Nilsen, R. A., Dutta, S., Samsonov D., and Hagiwara, A. 2006. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning. Phys. Med. Biol. 51, 4 (2006), 855--874. DOI= https://doi.org/10.1088/0031-9155/51/4/007
[7]
Noo, F., Clack, R., White T. A., and Roney T. J. 1998. The dual-ellipse cross vertex path for exact reconstruction of long objects in cone-beam tomography. Phys. Med. Biol. 43, 4 (1998), 797--810. DOI= https://doi.org/10.1088/0031-9155/43/4/009
[8]
Tang, X. and Ning, R. 2001. A cone beam filtered back-projection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit. Med. Phys. 28, 6 (2001), 1042--1055. DOI= https://doi.org/10.1118/1.1376444
[9]
Tuy, H. 1983. An inversion formula for cone-beam reconstruction. SIAM J. Appl. Math. 43, 3 (1983), 546--552. DOI= https://doi.org/10.1137/0143035
[10]
Feldkamp, L. A., Davis, L. C., and Kress, J. W. 1984. Practical cone-beam algorithm. J. Opt. Soc. Am. A. 1, 6 (1984), 612--619. DOI= https://doi.org/10.1364/JOSAA.1.000612
[11]
Wang, G., Lin, T. H., Cheng P. C., and Shinozaki, D. M. 1993. A general cone-beam reconstruction algorithm. IEEE Trans. Med. Imaging. 12, 3 (1993), 486--496. DOI= https://doi.org/10.1109/42.241876
[12]
Tang, X., Hsiech, J., Hagiwara, A., Nilsen, R. A., Thibault, J-B, and Drapkin, E. 2005. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory. Phys. Med. Biol. 50, 16 (2005), 3889--3905. DOI= https://doi.org/10.1088/0031-9155/50/16/016

Index Terms

  1. Z-range Extension of Volume Imaged with Clinical C-arm Computed Tomography from A Single Rotation Helical Cone-beam Scan

    Recommendations

    Comments

    Information & Contributors

    Information

    Published In

    cover image ACM Other conferences
    ISICDM 2019: Proceedings of the Third International Symposium on Image Computing and Digital Medicine
    August 2019
    370 pages
    ISBN:9781450372626
    DOI:10.1145/3364836
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

    In-Cooperation

    • Xidian University

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 24 August 2019

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. C-arm
    2. CT
    3. Computed Tomography
    4. Cone-beam
    5. Cone-beam Artifacts

    Qualifiers

    • Research-article
    • Research
    • Refereed limited

    Conference

    ISICDM 2019

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • 0
      Total Citations
    • 23
      Total Downloads
    • Downloads (Last 12 months)1
    • Downloads (Last 6 weeks)1
    Reflects downloads up to 05 Mar 2025

    Other Metrics

    Citations

    View Options

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    Figures

    Tables

    Media

    Share

    Share

    Share this Publication link

    Share on social media