ABSTRACT
As a potential solution for solving the hemolysis problem inside the narrow bearing clearance of hydrodynamically levitated blood pumps, plasma skimming has been observed and verified with spiral groove bearings. The objective of this study is to investigate and improve the plasma skimming effect by including the consideration of the red blood cells (RBCs) flow for the hydrodynamic bearing groove shape design. We designed a test rig to imitate the shear flow conditions inside the hydrodynamic bearing clearance. By visualizing RBCs inside the bearing clearance, plasma skimming efficiency with three different designs of groove shapes, referring to PlateA, PlateB, and PlateC, were evaluated and compared under a clearance size of 25 μm, a rotational speed of 2400 rpm, and a flow rate of 150 ml/min conditions. The flow of RBCs inside the clearance was photographed by a high-speed camera with a magnification lens. The plasma skimming efficiency was evaluated by comparing the measured hematocrit using the camera and the measured hematocrit of blood in the circuit. The in vitro blood tests were repeated three times for each designed groove shape with 1%-5% hematocrit human blood as the working fluid. The Student's t-test result of plasma skimming efficiency among three designed shapes showed that there was a significant difference between PlateA and PlateC at hematocrit of 5%, 4%, 3% and 2%, respectively. It is testified that the groove shapes of hydrodynamic bearings have a significant influence on the plasma skimming effect occurring in the bearing clearance.
- Adachi Iki, Burki Sarah, Zafar Farhan and Morales David Luis Simon. Pediatric ventricular assist devices. (2015). Journal of Thoracic Disease. 7, 12, 2194-2202. DOI: https://doi.org/10.3978/j.issn.2072-1439.2015.12.61.Google ScholarCross Ref
- Burki Sarah and Adachi Iki. Pediatric ventricular assist devices: Current challenges and future prospects. (2017). Vascular Health and Risk Management. 13, 177-185. DOI: https://doi.org/ 10.2147/VHRM.S82379.Google ScholarCross Ref
- Leslie Laura J., Marshall Lindsay J., Devitt Andrew, Hilton Andrew and Tansley Geoff D. (2013) Cell Exclusion in Couette Flow: Evaluation Through Flow Visualization and Mechanical Forces. Artificial Organs. 37, 3, 267-275. DOI: https://doi.org/10.1111/j.1525-1594.2012.01561.x.Google ScholarCross Ref
- Murashige Tomotaka, Sakota Daisuke, Kosaka Ryo, Nishida Masahiro, Kawaguchi Yasuo, Yamane Takashi and Maruyama Osamu. (2016). Plasma Skimming in a Spiral Groove Bearing of a Centrifugal Blood Pump. Artificial Organs. 40, 9, 856-866. DOI: https://doi.org/10.1111/aor.12799.Google ScholarCross Ref
- Jiang Ming, Murashige Tomotaka, Sakota Daisuke, Kosaka Ryo and Hijikata Wataru. (2019). Evaluating Plasma Skimming with Whole Blood in Small Gap Region Imitating Clearance of Blood Pumps. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 5665-5669. DOI: https://doi.org/10.1109/EMBC.2019.8857735.Google ScholarCross Ref
- Sakota Daisuke, Kondo Kazuki, Kosaka Ryo, Nishida Masahiro and Maruyama Osamu. Plasma skimming efficiency of human blood in the spiral groove bearing of a centrifugal blood pump. (2020). Journal of Artificial Organs. 1-9 pages. DOI: https://doi.org/10.1007/s10047-020-01221-9.Google ScholarCross Ref
- Fåhræus Robin and Lindqvist Torsten. (1931). The viscosity of the blood in narrow capillary tubes. American Journal of Physiology-Legacy Content. 96, 3, 562–568. DOI: https://doi.org/10.1152/ajplegacy.1931.96.3.562.Google ScholarCross Ref
- Palmer A. A. (1965). Axial drift of cells and partial plasma skimming in blood flowing through glass slits. American Journal of Physiology-Legacy Content. 209, 6, 1115-1122. DOI: https://doi.org/10.1152/ajplegacy.1965.209.6.1115.Google ScholarCross Ref
- Kosaka Ryo, Yasui Kazuya, Nishida Masahiro, Kawaguchi Yasuo, Maruyama Osamu, Yamane Takashi. (2014). Optimal bearing gap of a multiarc radial bearing in a hydrodynamically levitated centrifugal blood pump for the reduction of hemolysis. Artificial Organs.38, 9, 818-822. DOI: https://doi.org/10.1111/aor.12383Google ScholarCross Ref
- Amaral Felipe, Egger Christina, Steinseifer Ulrich and Schmitz-Rode Thomas. (2013). Differences between blood and a newtonian fluid on the performance of a hydrodynamic bearing for rotary blood pumps. Artificial Organs. 37, 9, 786-792. DOI: https://doi.org/10.1111/aor.12166.Google ScholarCross Ref
- Kink Thomas and Reul Helmut. (2003). Concept for a New Hydrodynamic Blood Bearing for Miniature Blood Pumps. Artificial Organs. 28, 10, 916-920. DOI: https://doi.org/10.1111/j.1525-1594.2004.07387.x.Google ScholarCross Ref
- Amaral Felipe, Groß-Hardt Sascha, Timms Daniel, Egger Christina, Steinseifer Ulrich and Schmitz-Rode Thomas. (2013). The spiral groove bearing as a mechanism for enhancing the secondary flow in a centrifugal rotary blood pump. Artificial Organs. 37, 10, 866-874. DOI: https://doi.org/10.1111/aor.12081.Google ScholarCross Ref
Recommendations
Hydrodynamic interaction between two red blood cells in simple shear flow: its impact on the rheology of a semi-dilute suspension
Blood is a suspension of red blood cells (RBCs) and its rheology is important when discussing the physiology of the cardiovascular system. In this study, we performed a numerical investigation of the rheological properties of an RBC suspension from the ...
Mechanical blood pumps for cardiac assistance
Cardiac assist devices are classified into the traditional engineering categories of displacement and rotary pumps. Clinical use and indications of the various pump categories are outlined and a detailed description of currently available systems is ...
Ultrasonic Visualization of Dynamic Behavior of Red Blood Cells in Flowing Blood
It is well known that the scatter of ultrasound by blood is mainly attributed to red blood cells (RBCs) and RBC aggregation. In the present review, researches of hemodynamic influence on RBC aggregation and ultrasound backscatter from blood were ...
Comments