Can Capillary Refill Time (CRT) measurement be a reliable clinical test?

Published: 05 April 2024 Publication History

Abstract

Visually, the state of peripheral circulation in the body can be seen in the prolonged capillary refill time (CRT) when there are peripheral circulation disorders. Various forms of shock, organ failure, frostbite, and vasculitis are associated with prolonged capillary refill time. Given that this index is currently measured mainly by clinicians with the naked eye, it is lack of consensus on the measurement method, resulting extremely large measurement errors. This limits the application in clinical practice controversial. An examination of CRT's clinical utilization, its emotional components, and novel approaches to gauging CRT that could potentially facilitate more precise clinical tests for monitoring the condition of human peripheral circulation is presented in the review.In addition, our laboratory provides a new method for measuring CRT - a fully automatic capillary refill time measurement instrument based on PID pressure control, which introduces optical sensors instead of human eyes to record the change of light intensity in the subject area and can quantify and control the pressure by PID system, which reduces the influence of human factors on the measurement to a certain extent. This technology introduces an optical sensor instead of the human eye to record the light intensity changes in the subject area and can quantify and control the pressure through a PID system, which reduces the influence of human factors on the measurement results and improves the accuracy of the measurement.

References

[1]
Mouncey PR,Osborn TM,Power GS,et al. Trial of early, goal-directed resuscitation for septic shock[J].N Engl J Med, 2015, 372(14):1301-1311.
[2]
ARISE Investigators, ANZICS Clinical Trials Group,Peake SL,et al.Goal-directed resuscitation for patients with early septic shock[J].N Engl J Med, 2014, 371(16):1496-1506.
[3]
Asfar P,Meziani F,Hamel JF,et al.SEPSISPAM Investigators: High versus low blood-pressure target in patients with septic shock[J].N Engl J Med, 2014,370(17):1583-1593.
[4]
Liu D W, "Critical care hemodynamic therapy - Beijing consensus." Chinese Journal of Internal Medicine 54.03. 2015: 248-271.
[5]
Pickard A, Karlen W, Ansermino JM. Capillary refill time: is itstill a useful clinical sign? Anesth Analg 2011; 113:120–3.
[6]
Champion HR,Sacco WJ,Copes WS,et al.A revision of the Trauma Score[J].J Trauma, 1989, 29(5):623-629.
[7]
Lara B, Enberg L, Ortega M, Capillary refill time during fluid resuscitation in patients with sepsis-related hyperlactatemia at the emergency department is related to mortality. PLoS One 2017; 12:e0188548.
[8]
Hernandez G, Pedreros C, V eas E, Evolution of peripheral vs metabolic perfusion parameters during septic shock resuscitation. A clinical-physiologic study. J Crit Care 2012; 27:283-8.
[9]
Hernández G, Cavalcanti AB, Ospina-Tascón G, Dubin A, Hurtado FJ, Damiani LP, Friedman G, Castro R, Alegría L, Cecconi M, Teboul JL, Bakker J. Statistical analysis plan for early goal-directed therapy using a physiological holistic view - the ANDROMEDA-SHOCK: a randomized controlled trial. Rev Bras Ter Intensiva. 2018 Jul-Sept;30(3):253-263.
[10]
Castro R, Kattan E, Ferri G, Pairumani R, Valenzuela ED, Alegría L, Oviedo V, Pavez N, Soto D, Vera M, Santis C, Astudillo B, Cid MA, Bravo S, Ospina-Tascón G, Bakker J, Hernández G. Effects of capillary refill time-vs. lactate-targeted fluid resuscitation on regional, microcirculatory and hypoxia-related perfusion parameters in septic shock: a randomized controlled trial. Ann Intensive Care. 2020 Nov 2;10(1):150.
[11]
Yazici P, Ozsan I, Aydin U. Capillary refill time as a guide for operational decision-making process of autoimmune pancreatitis: Preliminary results. World J Gastrointest Surg. 2015 Jul 27;7(7):110-5.
[12]
Lima A, Jansen TC, van Bommel J, Ince C, Bakker J. The prognostic value of the subjective assessment of peripheral perfusion in critically ill patients. Crit Care Med. 2009 Mar;37(3):934-8.
[13]
Gorelick MH, Shaw KN, Baker MD. Effect of ambient temperature on capillary refill in healthy children. Pediatrics. 1993 Nov;92(5):699-702.
[14]
Anderson B, Kelly AM, Kerr D, Clooney M, Jolley D. Impact of patient and environmental factors on capillary refill time in adults. Am J Emerg Med. 2008 Jan;26(1):62-5.
[15]
]Schriger DL, Baraff L. Defining normal capillary refill: variation with age, sex, and temperature. Ann Emerg Med. 1988 Sep;17(9):932-5.
[16]
Raju NV, Maisels MJ, Kring E, Schwarz-Warner L. Capillary refill time in the hands and feet of normal newborn infants. Clin Pediatr (Phila). 1999 Mar;38(3):139-44.
[17]
Anderson B, Kelly AM, Kerr D, Clooney M, Jolley D. Impact of patient and environmental factors on capillary refill time in adults. Am J Emerg Med. 2008 Jan;26(1):62-5.
[18]
Brown LH, Prasad NH, Whitley TW. Adverse lighting condition effects on the assessment of capillary refill. Am J Emerg Med. 1994. 12:46–7.
[19]
Schriger DL, Baraff L. Defining normal capillary refill: variation with age, sex, and temperature. Ann Emerg Med. 1988 Sep;17(9):932-5. 3415066.
[20]
Espinoza ED, Welsh S, Dubin A. Lack of agreement between different observers and methods in the measurement of capillary refill time in healthy volunteers: an observational study. Rev Bras Ter Intensiva. 2014 Jul-Sep;26(3):269-76. 25295821; PMCID: PMC4188463.
[21]
Shinozaki K, Jacobson LS, Saeki K, Kobayashi N, Weisner S, Falotico JM, Li T, Kim J, Lampe JW, Becker LB. Does training level affect the accuracy of visual assessment of capillary refill time? Crit Care. 2019 May 6;23(1):157. 31060576; PMCID: PMC6501297.
[22]
Ait-Oufella H, Bige N, Boelle PY, Pichereau C, Alves M, Bertinchamp R, Baudel JL, Galbois A, Maury E, Guidet B. Capillary refill time exploration during septic shock. Intensive Care Med. 2014 Jul;40(7):958-64. Epub 2014 May 9. 24811942.
[23]
Alsma J, van Saase J, Nanayakkara PWB, Schouten W, Baten A, Bauer MP, The power of flash mob research: conducting a nationwide observational clinical study on capillary refill time in a single day. Chest. 2017. 151:1106–13.
[24]
Fleming S, Gill P, Jones C, Taylor JA, V an den Bruel A, Heneghan C, V alidity and reliability of measurement of capillary refill time in children: a systematic review. Arch Dis Child. 2015. 100:239–49.
[25]
Shavit I, Brant R, Nijssen-Jordan C, Galbraith R, Johnson DW. A novel imaging technique to measure capillary-refill time: improving diagnostic accuracy for dehydration in young children with gastroenteritis. Pediatrics. 2006 Dec;118(6):2402-8. 17142525.)
[26]
Blaxter LL, Morris DE, Crowe JA, Henry C, Hill S, Sharkey D, Vyas H, Hayes-Gill BR. An automated quasi-continuous capillary refill timing device. Physiol Meas. 2016 Jan;37(1):83-99. Epub 2015 Dec 7. 26642080; PMCID: PMC4770525.
[27]
John RT, Henricson J, Nilsson GE, Wilhelms D, Anderson CD. Reflectance spectroscopy: to shed new light on the capillary refill test. J Biophotonics. 2018 Jan;11(1). Epub 2017 May 24. 28544641.
[28]
Fleming S, Gill P, Jones C, Taylor JA, Van den Bruel A, Heneghan C, Thompson M. Validity and reliability of measurement of capillary refill time in children: a systematic review. Arch Dis Child. 2015 Mar;100(3):239-49. Epub 2014 Sep 26. 25260515.
[29]
Saito D, Nakada TA, Imaeda T, Takahashi N, Shinozaki M, Shimizu R, Nakaguchi T. Impact of posture on capillary refilling time. Am J Emerg Med. 2022 Jun;56:378-379. Epub 2021 Nov 7. 34776282.

Index Terms

  1. Can Capillary Refill Time (CRT) measurement be a reliable clinical test?

    Recommendations

    Comments

    Information & Contributors

    Information

    Published In

    cover image ACM Other conferences
    ISAIMS '23: Proceedings of the 2023 4th International Symposium on Artificial Intelligence for Medicine Science
    October 2023
    1394 pages
    ISBN:9798400708138
    DOI:10.1145/3644116
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than the author(s) must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected].

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 05 April 2024

    Permissions

    Request permissions for this article.

    Check for updates

    Qualifiers

    • Research-article
    • Research
    • Refereed limited

    Conference

    ISAIMS 2023

    Acceptance Rates

    Overall Acceptance Rate 53 of 112 submissions, 47%

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • 0
      Total Citations
    • 34
      Total Downloads
    • Downloads (Last 12 months)34
    • Downloads (Last 6 weeks)7
    Reflects downloads up to 17 Feb 2025

    Other Metrics

    Citations

    View Options

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    HTML Format

    View this article in HTML Format.

    HTML Format

    Figures

    Tables

    Media

    Share

    Share

    Share this Publication link

    Share on social media